Blocks for analog value functions

5.7.1

Triggered saving

Function
The block saves the current value of an analog input when a programmable event (Trigger)
occurs. With an edge change 0 → 1 of "Trigger" the value of the input is written to the output.
The "Reset" input resets the output to 0. As long as "Reset" is set to 1, the "Trigger" input is
ignored.
Parameters
Parameters
Input parameters
En
Trigger
Reset
RTU303xC
Operating Instructions, 06/2019, C79000-G8976-C382-06
Range of values
Digital output / bit
memory
Digital output / bit memory
Tag type / range of
Description
values
Enable parameter, see section Often used parameters
(Page 252).
True / False
With an edge change 0 → 1 block processing is started
and the value of "Input" is saved in the "Output".
Digital input / output /
bit memory
With the setting "True" an edge change 0 → 1 of the
trigger is evaluated in the first update cycle. The block is
STATUS_ERROR
processed only once.
With the setting "False" the block is never processed.
True / False
When there is an edge change 0 → 1 the output is reset
to 0.
Digital input / output /
bit memory
With the setting "TRUE" the function is actually turned
off.
STATUS_ERROR
With the setting "False" the output is never reset.
5.7 Blocks for analog value functions
Description
Tag for the value calculated by the block. Switching:
At sunrise: 1
At sunset: 0
Error display:
0: Permissible values at the "Latitude" and "Longi-
tude" input signals.
1: Impermissible values at the "Latitude" and "Lon-
gitude" input signals.
Program blocks
279