Chapter 2 Command System

:MEASure:SETup:TYPE

Syntax
:MEASure:SETup:TYPE <type>
:MEASure:SETup:TYPE?
Description
Sets or queries the type of the measurement setting.
Parameter
Name
Type
<type>
Discrete
Return Format
The query returns DEL, PHAS, or THR.

:MEASure:STATistic:DISPlay

Syntax
:MEASure:STATistic:DISPlay <bool>
:MEASure:STATistic:DISPlay?
Description
Enables or disables the statistic function of the measurement results; or queries the on/off status of the
statistic function of the measurement results.
Parameter
Name
Type
<bool>
Bool
Remarks
When the statistic function is enabled, the instrument makes statistics of the measurement results for at
most 5 measurement items that are turned on last time and displays the specified statistic items in the
statistic results (the items to be displayed are related to the statistic mode currently selected (refer to
the :MEASure:STATistic:MODE command)) at the bottom of the screen.
Return Format
The query returns 1 or 0.

:MEASure:STATistic:MODE

Syntax
:MEASure:STATistic:MODE <mode>
:MEASure:STATistic:MODE?
Description
Sets or queries the statistic mode.
Parameter
Name
Type
<mode>
Discrete
DS4000E Programming Guide
Range
{DELay|PHASe|THReshold}
Range
{{1|ON}|{0|OFF}}
Range
{EXTRemum|DIFFerence}
RIGOL
Default
DELay
Default
0|OFF
Default
EXTRemum
2-153