Refer to parameter P10.01 for details regarding above-mentioned sources of frequency
command.
 Decade: frequency command source bundled under terminal control (same as unit's place)
 Hundreds place: frequency command source bundled under communication control (same
as unit's place)
 ATTENTION:
Different run command sources can be bundled with the same frequency command
source.
The priority of frequency command sources bundled with run command overrides Group
P10.
P11.02
Running direction
This parameter applies to run command controlled by keypad, and disabled under terminal and
communication control.
0: Forward
1: Reverse
P11.03
Reverse disabled
0: Reverse enabled
1: Reverse disabled
In some applications, reverse is likely to result in equipment damage. This parameter is used to
prevent reverse running.
Dead time of forward
P11.04
The dead time with 0Hz output during the transition from forward to reverse, or from reverse to
forward is indicated by letter "t" in Fig.5-7.
P11.05
and reverse
输出频率
Output frequency
Fig.5-7 Dead time between forward and reverse
Start method
Chapter 5 Specification of Parameters
Range: 0~1
Range: 0~1
Range: 0.0s ~ 3600.0s
t
Range: 0~2
- 83 -
Factory default: 0
Factory default: 0
Factory default:
0.0s
时间
Time
Factory default: 0