Chapter 5 Specification of Parameters
Amplitude = P53.04 x current command frequency.
1: Relative to maximum frequency
Amplitude = P53.04 x maximum frequency P10.08.
Hundreds place: wobble frequency memorized when stop
0: Memory enabled
The drive memorizes the current wobble frequency state when stop. When restarted, drive
continues to run the wobble frequency with the memorized state at latest stop. Pre-frequency
of wobble frequency P53.02 is enabled at restart.
1: Memory disabled
When the drive is started, it restarts wobble frequency running. Run at pre-frequency of
wobble frequency P53.02, maintain this frequency for pre-frequency holding time P53.03,
and then automatically gets into wobble frequency control.
Thousands place: wobble frequency memorized on power loss
0: Memory enabled
Automatically save the wobble frequency state on power loss. This function takes effect only
under wobble frequency running.
1: Memory disabled
Drive clears wobble frequency status on power loss.
P53.02
Pre-wobble frequency
Pre-wobble frequency
P53.03
During the running of wobble frequency, P53.02 is the running frequency before the drive
begins to run at wobble frequency, while P53.03 is the holding time of pre-wobble frequency.
When P53.03 is set to 0, pre-frequency is disabled.
Wobble frequency
P53.04
The percentage is relative to center frequency or maximum frequency and determined by the
decade of P53.01. Center frequency is the command frequency set by parameters of Group 10.
Running frequency of wobble frequency is not only subject to this amplitude, but is also
restricted by upper limit and lower limit of frequency.
Hop frequency
P53.05
Hop frequency = P53.05 ● amplitude.
P53.06
Cycle of wobble frequency
holding time
amplitude
Range: 0.00Hz~600.00Hz
Range: 0.0s~3600.0s
Range: 0.0%~50.0%
Range: 0.0%~50.0%
Range: 0.1s~999.9s
- 162 -
E5 User Manual
Factory default:
0.00Hz
Factory default:
0.0s
Factory default:
0.0%
Factory default:
0.0%
Factory default:
0.0s