Chapter 5 Specification of Parameters
This parameter takes effect when P31.00 is set to 7 or 8.
0: digital setting by P31.19
Under V/f separated pattern 1, drive output voltage is completely determined by P31.19. 100%
corresponds to motor rated voltage.
Under V/f separated pattern 2, output voltage = voltage calculated according to linear V/f
curve x 2 x P31.19.
1: Set by AI1
2: Set by AI2
3: Reserved
Under V/f separated pattern 1, drive output voltage is completely determined by the selected
analog. The biggest setting is the motor rated voltage.
Under V/f separated pattern 2, output voltage = voltage calculated according to linear
V/f curve x the proportion determined by the analog input. The maximum set value can
be 200%.
4: Process PID output
Outputs voltage on the basis of process PID.
Under V/f separated pattern 1, output voltage is determined by the output of process PID.
Under V/f separated pattern 2, the output of process PID is a proportional value whose
maximum set value could be 200%. Then this proportional value is multiplied by the voltage
calculated according to linear V/f curve to obtain drive output voltage. Refer to parameter
Group P50 for information of process PID.
5: AI1 + process PID output
Under V/f separated pattern 1, drive output voltage is determined by "AI1 + process PID
output". The maximum set value of AI1 is motor rated voltage.
Under V/f separated pattern 2, "AI1 + process PID" output is a proportional value whose
maximum set value corresponds to 200%. This proportional value is multiplied by the voltage
calculated according to linear V/f to obtain drive output voltage.
Digital set voltage on V/f
P31.19
separated pattern
When 0 is selected at P31.18, the output voltage will be determined by P31.19.
Voltage variation time on
P31.20
V/f separated pattern
Sets the output voltage change rate under V/f separation pattern. This parameter value is the
time rising from 0V to motor rated voltage or dropping from rated voltage to 0V.
Group P32 Vector Control Parameters of Motor 1
Set control parameters in Group P32 when motor 1 is selected as current load motor on which
sensor-less vector control is performed.
Range: 0.0%~100.0%
Range: 0.00s~600.00s
- 132 -
E5 User Manual
Factory default:
0.0%
Factory default:
0.01s