Best E5 Series User Manual page 162

High-performance frequency inverter
Table of Contents

Advertisement

Chapter 5 Specification of Parameters
Decade: running direction (same as P52.01)
Hundreds place: Accel/Decel time option (same as P52.01)
P52.14
Running time of step 6
Sets the running time of step 6 of simple PLC. The time unit is set by thousands place of
P52.00.
P52.15
Setting of step 7
Unit's place: frequency setting
0: Multi-step frequency 7 (P51.09)
1~7: same as P52.01
Decade: running direction (same as P52.01)
Hundreds place: Accel/Decel time option (same as P52.01)
P52.16
Running time of step 7
Sets the running time of step 7 of simple PLC. The time unit is set by thousands place of
P52.00.
P52.17
Setting of step 8
Unit's place: frequency setting
0: Multi-step frequency 8 (P51.10)
1~7: same as P52.01
Decade: running direction (same as P52.01)
Hundreds place: Accel/Decel time option (same as P52.01)
P52.18
Running time of step 8
Sets the running time of step 8 of simple PLC. The time unit is set by thousands place of
P52.00.
P52.19
Setting of step 9
Unit's place: frequency setting
0: Multi-step frequency 9 (P51.11)
1~7: same as P52.01
Decade: running direction (same as P52.01)
Range: 0.0~6000.0s(min)
Range: 000~327
Range: 0.0~6000.0s(min)
Range: 000~327
Range: 0.0~6000.0s(min)
Range: 000~327
- 158 -
E5 User Manual
Factory default:
0.0s
Factory default:
000
Factory default:
0.0s
Factory default:
000
Factory default:
0.0s
Factory default:
000