Best E5 Series User Manual page 103

High-performance frequency inverter
Table of Contents

Advertisement

E5 User Manual
When the drive fault occurs, this enabled terminal will reset the fault. This function is the
same with RESET key on keypad.
24: Pulse input (valid only for X6/DI)
This is valid only for digital input terminal X6/DI. This terminal receives pulse signal as
frequency command. Refer to P22.24~P22.27 for the relationship between pulse signal and
command frequency.
When pulse input is selected as the frequency command, X6/DI terminal must be set to
"pulse input" (P20.07 is set to 24).
25: Motor 1/2 switchover
The loaded motor can be selected via this terminal as shown in Table5-5:
P00.08
0
0
1
1
Set parameters of motor 1 in parameter groups P30~P32, and set parameters of motor 2
in
groups P33~P35.
26: Reserved
27: Run command switched to keypad control
This terminal should be enabled by trigger edge. When this terminal status is switched from
OFF to ON, run command will be switched to keypad control.
28: Run command switched to terminal control
This terminal should be enabled by trigger edge. When this terminal status is switched from
OFF to ON, run command will be switched to terminal control.
29: Run command switched to communication control
This terminal should be enabled by trigger edge. When this terminal is switched from OFF
to ON, run command will be switched to communication control.
30: Frequency command pattern shift
When P10.00 is set to 2, 3 and 4, switch during various frequency command patterns can
be performed via "frequency command patterns shift" terminal.
When P10.00 is set to 2, this terminal shall shift between master frequency command
and auxiliary frequency command.
When P10.00 is set to 3, this terminal shall shift between master frequency command,
and master & auxiliary computation result.
When P10.00 is set to 4, this terminal shall shift between auxiliary frequency command,
and master & auxiliary computation result.
Table5-5
Motor 1/2 switchover
terminal
OFF
ON
OFF
ON
- 99 -
Chapter 5 Specification of Parameters
Loaded motor
Motor 1
Motor 2
Motor 2
Motor 1

Advertisement