Used with "count input" terminal, to clear pulse count value.
39: Length count
It is used for fixed-length control, and only takes effect on digital input terminal X6/DI. The
length is calculated via pulse input. Please refer to specification of parameters
P53.08~P53.11 for details. When the length is attained, digital output terminal "length
attained" shall output effective signal. The current length value will be memorized on power
loss.
40: Length clear
Used with "length count" terminal, to clear the length calculated.
41~62 Reserved
63: Simple PLC paused
When simple PLC is running and this terminal is enabled, the current PLC status (running
time and step) will be memorized, and the drive will run at 0Hz. When this terminal is
disabled, the drive restores its running from the memorized moment.
64: Simple PLC disabled
When simple PLC is running, and this terminal is enabled. The status of PLC will be cleared
and the output frequency is 0Hz. When this terminal is disabled again, the drive resumes
PLC running from step 0.
65: Simple PLC stop memory clear
Under simple PLC running, if this terminal is enabled in stop status, the memorized
information of PLC running step, running time and running frequency will be all cleared.
Refer to parameter Group P52 for more information.
66: Start wobble frequency
This terminal takes effect only when P53.00 is set to "1: wobble frequency function enabled
" and P53.01 unit's place is set to "started through terminal".
When this terminal is disabled, the drive runs at preset wobble frequency set by P53.02.
When this terminal is enabled, the drive would activate wobble-frequency running
immediately. Refer to Group P53 for details of wobble frequency.
67: Clear wobble frequency status
When the drive is running at wobble frequency, if this terminal is enabled, the memorized
wobble frequency status will be cleared, no matter which wobble frequency start method
(automatic/ via terminal) is taken. When this terminal is disabled, wobble frequency would
resume. Refer to Group P53 for information of wobble frequency.
68: Running prohibited
When this terminal is enabled, the drive will coast to stop if it's running, and will prohibit start
running if it's in a standby state. This terminal mainly applies to the situation where safety
interlocking is required. Only after this terminal becomes disabled, the drive can be
restarted.
69: DC brake in running
When this terminal is enabled, the drive will immediately fall into DC brake. After the
terminal becomes disabled, the drive will be restored to normal state and ramp up to the
Chapter 5 Specification of Parameters