Chapter 5 Specification of Parameters
communication data addresses are not supported. As slave, this drive can only receive the
data.
P60.06
Parameter store address
0: P10.02
1: P50.01
Enabled when P60.05 is set to 2. This parameter sets the store address of received data when
it works as slave.
Proportional factor of received
P60.07
Enabled when P60.05 is set to 2. Received data is multiplied by P60.07 and then put the result
into the address set by P60.06. This parameter setting is very useful when a master drive
control a number of slave drives and needs to allocate the frequency.
Group L Keys and Display of Keypad
Group P70 Keys of Keypad
P70.00
0: No function
1: Forward jog
2: Reverse jog
3: Forward/reverse switchover
4: Emergency stop 1 (set Decel time on P12.09)
5: Emergency stop 2 (coast to stop)
6: Run command sources shifted (keypad/terminal/communication)
P70.01
Keys locked option
0: Not locked
1: Full locked
2: Keys locked other than RUN, STOP/RESET
3: Keys locked other than STOP/RESET
4: Keys locked other than >>
P70.02
Function of STOP key
0: STOP key valid only when under keypad control
1: STOP key valid under any run command source
frequency
MF key setting
Range: 0~1
Range: 0.0%~100.0%
Range: 0~6
Range: 0~4
Range: 0~1
- 166 -
E5 User Manual
Factory default: 0
Factory default:
100.0%
Factory default: 0
Factory default: 0
Factory default: 0