Chapter 4 List of Parameters
Param.
Designation
Range of auxiliary
P10.05
frequency
Coeff of auxiliary
P10.06
frequency
Computation of master
P10.07
and auxiliary frequency
command
Maximum frequency
P10.08
P10.09
Upper limit frequency
Lower limit frequency
P10.10
Operation when
command frequency
P10.11
lower than lower limit
frequency
Time-delay of stop when
command frequency
P10.12
lower than lower limit
frequency
Lower limit of skip
P10.13
frequency band 1
Upper limit of skip
P10.14
frequency band 1
Lower limit of skip
P10.15
frequency band 2
Upper limit of skip
P10.16
frequency band 2
Lower limit of skip
P10.17
frequency band 3
Upper limit of skip
P10.18
frequency band 3
P10.19
Jog frequency
Run command
P11.00
Binding of run command
P11.01
and frequency command
Scope
0: Relative to maximum frequency
1: Relative to master frequency
0.0%~100.0%
0: Master + auxiliary
1: Master - auxiliary
2: Max {master, auxiliary}
3: Min {master, auxiliary}
Upper limit frequency ~600.00Hz
Lower limit frequency ~ maximum
frequency
0.00Hz~upper limit frequency
0: Run at lower limit frequency
1: Run at 0 Hz
2: Stop
0.0s ~ 6553.5s
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
0.00Hz~upper limit frequency
Group 11: Start/Stop Control
0: Keypad control
1: Terminal control
2: Communication control
Unit's place: frequency command
source bundled under keypad
control:
0: No binding
- 30 -
E5 User Manual
Factory
Attr
Default
0
100.0%
0
50.00Hz
50.00Hz
0.00Hz
0
0.0s
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
0.00Hz
5.00Hz
0
000