Group P52 Simple PLC
Running mode of simple
P52.00
PLC
Unit's place: PLC running mode
0: Stop after a single cycle
PLC stops upon the completion of one cycle and it won't be started unless another run
command is given, shown as Fig.5-20.
1: Continue to run with the last frequency after a single cycle
After the completion of one cycle, PLC maintains the running frequency and direction of the
last step. See the figure below:
2: Repeat cycles
PLC automatically starts the another cycle after finishing one until there is a stop command.
Decade: power loss memory
0: Memory disabled on power loss
The drive does not memorize PLC running status on power loss and starts the running from
step 0 after power up again.
1: Memory enabled on power loss
The drive saves PLC running status on power loss, including the running step, running
frequency and finished running time at the moment of power loss. After the next power up,
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Range: 0000~1212
- 154 -
E5 User Manual
7(P51.09)
Multi-step frequency
8(P51.10)
Multi-step frequency
9(P51.11)
Multi-step frequency
10(P51.12)
Multi-step frequency
11(P51.13)
Multi-step frequency
12(P51.14)
Multi-step frequency
13(P51.15)
Multi-step frequency
14(P51.16)
Multi-step frequency
15(P51.17)
Factory default:
0000