E5 User Manual
23: Designated count value attained
Refer to the specification of parameter P53.13.
24: Length attained
Refer to the specification of parameters P53.08~P53.11.
25: Consecutive running time attained
When consecutive running time attains the value of
outputs ON. Consecutive running time is cleared when stop.
26: Accumulative running time attained
When accumulative running time attains the value of
outputs ON. Accumulative running time is maintained when stop.
27: Contracting brake control
Refer to the specification of parameters P40.05~ P40.11 for details.
28: Positioning finished
Under the mode of motor spindle orientation or simple feed, when the difference between
the detected position by encoder and command position is less than F4-01, also the lasting
time attains value of F4.02, this terminal outputs ON as finish of positioning.
29: Positioning imminent
Under pulse train position control, When the difference between the pulse detected by
encoder and command pulse is less than value of F4-01, this terminal outputs ON.
30: PLC step completed
Upon the completion of current step of simple PLC running, ON signal with the width of
500ms will be output.
31: PLC cycle completed
Upon the completion of a cycle of simple PLC running, ON signal with a width of 500ms will
be output.
32: Wobble frequency attains to upper or lower limit frequency
When drive output frequency attains upper limit frequency P10.09 or lower limit frequency
P10.10 under wobble frequency running, ON signal will be output.
33~99: Reserved
P21.04
Y1 output delay time
P21.05
Y2 output delay time
Relay 1 output delay
P21.06
time
Relay 2 output delay
P21.07
time
These three parameters define the delay response time of digital output terminals Y1 & Y2,
relay 1 and relay 2.
Range: 0.0s~3600.0s
Range: 0.0s~3600.0s
Range: 0.0s~3600.0s
Range: 0.0s~3600.0s
- 109 -
Chapter 5 Specification of Parameters
P40.03, corresponding terminal
P40.04, corresponding terminal
Factory default: 0.0s
Factory default: 0.0s
Factory default: 0.0s
Factory default: 0.0s