command, the frequency that corresponds to maximum value of the source should be
(P10.08●P10.06)
Example:
Select AI1 as auxiliary frequency command source (set P10.03 to 3) and set AI1 to curve 1
(unit's place of P22.00 is 0) as shown in Fig.5-2. In such a case, the frequency that
corresponds to the maximum input of curve 1 should be: (P22.02) ● [(P10.08) ● (P10.06)].
Set value that corresponds to
maximum input of curve 1
Set value that corresponds to
minimum input of curve 1
When X6/DI pulse input is selected as auxiliary frequency command (set P10.03 to 6), the
frequency that corresponds to maximum DI input should be: (P22.25) ● [(P10.08) ● (P10.06)].
When PID is selected for auxiliary frequency command, the frequency that corresponds to
maximum value of PID output should be (P10.08) ● (P10.06).
PID output diagrammatic sketch is as shown in Fig.5-2.
When P10.05 is set to 1 (relative to master frequency):
When AI1, AI2, RESERVED, or X6/DI pulse input is selected for auxiliary frequency
command source, the frequency that corresponds to maximum value of these sources should
be:
[master frequency ● (P10.06)].
Example:
Corresponding set value
对应设定值
曲线1最大输入对应
设定值(C2-02)
(P22.02)
曲线1最小输入对应
(P22.04)
设定值(C2-04)
曲线1最小输入
Minimum input of
(C2-03)
curve 1 (P22.03)
频率输出
Frequency output
(b0-08)×(b0-06)
P10.08*P10.06
0
0
Chapter 5 Specification of Parameters
曲线1最大输入
Maximum
(C2-01)
input of curve
1 (P22.01)
Fig. 5-1
PID输出
PID output
最大值
Maximum value
Fig. 5-2
- 77 -
AI analog
AI模拟量