Param.
Designation
P71.03
Linear speed COEFF
P80.00
Running frequency
P80.01
Set frequency
P80.02
Bus voltage
P80.03
Output voltage
P80.04
Output current
P80.05
Output torque
P80.06
Output power
Master frequency
P80.07
command source
Auxiliary frequency
P80.08
command source
BIT0: Running linear speed (m/s)
BIT1: Set linear speed (m/s)
BIT2: External count value
BIT3: DI
Note: when this function code is
set to 0000, the set frequency
would be displayed as default (Hz)
0.1%~999.9%
Group P80
Status Monitoring
0.00Hz~600.00Hz
0.00Hz~600.00Hz
0V~65535V
0V~65535V
0.0A~6553.5A
0.0%~300.0%
0.0%~300.0%
0: Digital setting + adjustment
through ∧/∨ on keypad
1: Digital setting + terminal
UP/DOWN adjustment
2: Analog input AI1
3: Analog input AI2
4: Reserved
5: X6/DI pulse input
6: Process PID output
7: PLC
8: Multi-step frequency
9: Communication
0: No command
1: Digital setting + adjustment
through ∧/∨ on keypad
2: Digital setting + terminal
UP/DOWN adjustment
3: Analog input AI1
4: Analog input AI2
5: Reserved
6: X6/DI pulse input
7: Process PID output
8: PLC
9: Multi-step frequency
10: Communication
- 63 -
Chapter 4 List of Parameters
Scope
Factory
Attr
Default
100.0%
×
0.00Hz
×
0.00Hz
×
0V
×
0V
×
0.0A
×
0.0%
×
0.0%
×
0
×