Best E5 Series User Manual page 52

High-performance frequency inverter
Table of Contents

Advertisement

Chapter 4 List of Parameters
Param.
Designation
P35.08
ASR output filtering time
P35.09
ACR proportion coeff Kp
P35.10
ACR integration coeff Ki
P35.11
Pre-excitation time
Electric-driven torque
P35.12
limitation source
Limitation mode of
P35.13
braking torque
Digital setting of
P35.14
electric-driven torque
Digital setting of brake
P35.15
torque
Torque limit coefficient in
P35.16
flux weakening
Electric-driven slip
P35.17
compensation gain
Brake slip compensation
P35.18
gain
Carrier frequency
P40.00
P40.01
Reserved
0.0ms~500.0ms
0.000~4.000
0.000~4.000
0.000s~5.000s
0: P35.14 digital setting
1: Analog input AI1
2: Analog input AI2
3: Reserved
4: X6/DI pulse input
5: Communication
0: P35.15 digital setting
1: Analog input AI1
2: Analog input AI2
3: Reserved
4: X6/DI pulse input
5: Communication
0.0%~200.0%
0.0%~200.0%
0.0%~100.0%
10.0%~300.0%
10.0%~300.0%
Group P40 Enhanced function
≤15kW:
0.7kHz~16.0kHz, factory default:
8.0 kHz
18.5kW~45kW:
0.7kHz~10.0kHz, factory default:
4.0 kHz
55kW~75kW:
0.7kHz~16.0kHz, factory default:
3.0 kHz
≥90kW:
0.7kHz~3.0kHz, factory default:
2.0 kHz
Reserved
- 48 -
Scope
E5 User Manual
Factory
Attr
Default
0.3ms
1.000
1.000
0.200s
0
0
180.0%
180.0%
50.0%
100.0%
100.0%
Model
defined
Reserved

Advertisement