Chapter 4 List of Parameters
Param.
Designation
Overload alarm
P41.04
threshold
Overload alarm
P41.05
activated time that
exceeding threshold
P41.06
Protection action 1
P41.07
Protection action 2
Scope
1: Detect at constant speed only
Decade: compared object:
0: Rated current of motor
1: Rated current of drive
Hundreds place: alarm option
0: Fault reported and continue to
run
1: Fault reported and coast to stop
20.0%~200.0%
0.1s~60.0s
Unit's place: encoder
disconnection action:
0: Fault reported and coast to stop
1: Fault reported but continue to
run
Decade: temperature sampling
disconnection action:
0: Fault reported and coast stop
1: Fault reported and continue to
run
Hundreds place: abnormal
EEPROM :
0: Fault reported and coast stop
1: Fault reported and continue to
run
Thousands place: abnormal
terminal communication:
0: Fault reported and coast stop
1: Fault reported and continue to
run
Unit's place: abnormal keypad
communication:
0: Fault reported and coast stop
1: Fault reported and continue to
run
Decade: current detection circuit
failed
0: Fault reported and coast stop
1: Fault reported and continue to
- 50 -
E5 User Manual
Factory
Attr
Default
○
130.0%
○
5.0s
●
0000
●
0000