E5 User Manual
The time of the completion of a complete process of wobble frequency
P53.07
Triangular wave ramp-up time
Sets the wobble frequency running time of ramp-up segment.
Triangular wave ramp up time = P53.07 ● P53.06
Wobble frequency ramp-down time = P53.06 - triangular wave ramp-up time
 ATTENTION:
The current wobble frequency status can be cleared by digital input terminal "clear
wobble frequency status " in stop status.
If the output frequency exceeds upper limit frequency or lower limit frequency during
the running at wobble frequency, digital output terminal " wobble frequency attains to
upper or lower limit frequency " outputs ON signal
Parameters P53.08~P53.11 are for fixed-length stop.
P53.08
0: m
1: 10m
P53.09
Length setting
Sets the length value of fixed-length stop. When set to 0, fixed-length stop function is enabled,
but the actual length is still calculated. When it is detected the actual length attains this set
value, digital output terminal "length attained" will output ON signal and perform the command
set by P53.11.
Number of pulses per
P53.10
Input pulse is received via digital input terminal "length count"; the number of pulses per meter
is set here.
Command when the length
P53.11
0: Not stop
1: Stop
This parameter sets the action of the drive when actual length attains the length set by P53.09.
Actual length can be cleared through digital input terminal "length clear".
 ATTENTION:
When actual length is detected to attain the set length, digital output terminal "length
Length unit
meter
attained
Chapter 5 Specification of Parameters
Range: 0.0%~100.0%
Range: 0~1
Range: 0~65535
Range: 0.1~6553.5
Range: 0~1
- 163 -
Factory default:
0.0%
Factory default: 0
Factory default:
1000
Factory default:
100.0
Factory default: 0