Chapter 5 Specification of Parameters
9: Communication
Upper computer is the master frequency command source of the drive through standard
RS485 communication interface on the drive..
refer to Group P60 and appendix on this manual for further information about
communication protocol, and programming, etc.
 ATTENTION:
Master frequency command can be forcibly switched to P10.02 via terminal "master
frequency command switched to digital setting P10.02". When this terminal is disabled,
master frequency command is determined by P10.01. When terminal is enabled, master
frequency command shall be the value of P10.02.
Digital setting of master
P10.02
When master frequency command source P10.01 is set to either 0 or 1, this parameter value
will be the initial value of master frequency command.
Auxiliary frequency
P10.03
command source
0: No command
Auxiliary frequency command is disabled, and auxiliary frequency is 0.
1~10: See 0~9 specifications of P10.01
Digital setting of
P10.04
auxiliary frequency
When auxiliary frequency command is set to either 1 or 2, this parameter value should be the
initial value of auxiliary frequency command.
Range of auxiliary
P10.05
0: Relative to maximum frequency
1: Relative to master frequency
See P10.06 specification for details.
Coeff of auxiliary
P10.06
frequency command
When P10.03 selects AI1, AI2, RESERVED, X6/DI pulse input, or process PID output as
auxiliary frequency command sources, P10.05 and P10.06 will determine the final output value
of auxiliary frequency command.
When P10.05 is set to 0 (relative to maximum frequency):
When AI1, AI2, RESERVED, X6/DI pulse input is selected for auxiliary frequency
frequency
frequency
Range: lower limit frequency ~
upper limit frequency
Range: 0~10
Range: lower limit frequency ~
upper limit frequency
Range: 0~1
Range: 0.0%~100.0%
- 76 -
E5 User Manual
Factory default:
50.00Hz
Factory default:
0
Factory default:
0.00Hz
Factory default: 0
Factory default:
100.0%