E5 User Manual
Param.
Designation
Filtering time of digital
P20.11
input terminal
Delay time of terminal
P20.12
X1
Delay time of terminal
P20.13
X2
Digital input terminal
P20.14
enabled status setting 1
Digital input terminal
P20.15
enabled status setting 2
Digital input terminal
P20.16
enabled status setting 3
Terminal UP/DOWN
frequency adjustment
P20.17
control
Scope
66: Start wobble frequency
67: Clear wobble frequency status
68: Running prohibited
69: DC injection braking at running
70~99: Reserved
0.000s~1.000s
0.0s~3600.0s
0.0s~3600.0s
Unit's place: X1
0: Positive logic
1: Negative logic
Decade: X2 (same as unit's place)
Hundreds place: X3 (same as
unit's place)
Thousands place: X4 (same as
unit's place)
Unit's place: X5
0: Positive logic
1: Negative logic
Decade: X6 (valid as ordinary
terminal, same as unit's place)
Hundreds place: reserved)
Thousands place: reserved
Unit's place: AI1
0: Positive logic
1: Negative logic
Decade: AI2 (same as unit's place)
Hundreds place: Reserved
Thousands place: reserved
Unit's place: action when stop
0: Clear
1: Holding
Decade: action on power loss
0: Clear
1: Holding
Hundreds place: integral function
0: No integral function
1: Integral function enabled
- 35 -
Chapter 4 List of Parameters
Factory
Attr
Default
0.010s
0.0s
0.0s
0000
0000
0000
0000
○
○
○
●
●
●
○