Chapter 5 Specification of Parameters
2: Accel/Decel time 3
3: Accel/Decel time 4
The Accel/Decel time of simple PLC running is set here, not determined by digital input terminal
"Accel/Decel time determinant 1~2". In addition, Accel/Decel time unit is set through thousands
place of P52.00 and is independent of the setting of P12.00.
P52.02
Running time of step 0
Sets the running time for step 0 of simple PLC and the time unit is set by thousands place of
P52.00.
P52.03
Setting of step 1
Unit's place: frequency setting
0: Multi-step frequency 1 (P51.03)
1~7: same as P52.01
Decade: running direction (same as P52.01)
Hundreds place: Accel/Decel time option (same as P52.01)
Running time of step 1
P52.04
Sets the running time for step 1 of simple PLC and the time unit is set by thousands place of
P52.00.
Setting of step 2
P52.05
Unit's place: frequency setting
0: Multi-step frequency 2 (P51.04)
1~7: same as P52.01
Decade: running direction (same as P52.01)
Hundreds place: Accel/Decel time option (same as P52.01)
Running time of step 2
P52.06
Sets the running time of step 2. The time unit is set by thousands place of P52.00.
Setting of step 3
P52.07
Unit's place: frequency setting
0: Multi-step frequency 3 (P51.05)
Range: 0.0~6000.0s(min)
Range: 000~327
Range: 0.0~6000.0s(min)
Range: 000~327
Range: 0.0~6000.0s(min)
Range: 000~327
- 156 -
E5 User Manual
Factory default:
0.0s
Factory default:
000
Factory default:
0.0s
Factory default:
000
Factory default:
0.0s
Factory default:
000