Best E5 Series User Manual page 142

High-performance frequency inverter
Table of Contents

Advertisement

Chapter 5 Specification of Parameters
Input source of temperature
P33.25
transducer signal of motor 2
Thermal protection threshold of
temperature transducer of motor
P33.26
2
Group P34
V/f Control Parameters of Motor 2
When motor 2 is selected as current loaded motor, under V/f control pattern, please set control
parameters in Group P34. The specification of V/f control parameters Group P34 of motor 2 is
the same with that of V/f control parameters Group P31 of motor 1.
P34.00 V/f curve setting
P34.01 V/f frequency value f3
P34.02 V/f voltage value V3
P34.03 V/f frequency value f2
P34.04 V/f voltage value V2
P34.05 V/f frequency value f1
P34.06 V/f voltage value V1
P34.07 V/f frequency value f0
P34.08 V/f voltage value V0
P34.09 Torque boost
P34.10 Slip compensation gain
P34.11 Droop control
P34.12 Current limitation mode
Digital setting of current limit
P34.13
value
Current limit coeff on field
P34.14
weakening
P34.15 Energy saving percentage
P34.16 V/f oscillation suppression gain 1 Range: 0~3000
Range: 0~2
Range: 0.00V~10.00V
Range: 0~8
Range: 0.00Hz~rated
frequency of motor
Range: 0.0%~100.0%
Range: P34.05~
P34.01
Range: 0.0%~100.0%
Range: P34.07~
P34.03
Range: 0.0%~100.0%
Range: 0.00Hz~
P34.05
Range: 0.0%~100.0%
Range: 0.0%~30.0%
Range: 0.0%~300.0%
Range:
0.00Hz~maximum
frequency
Range: 0~5
Range:
20.0%~200.0%
Range: 0.001~1.000
Range: 0.0%~40.0%
- 138 -
E5 User Manual
Factory default: 0
Factory default:
10.00V
Factory default: 0
Factory default:
50.00Hz
Factory default:
100.0%
Factory default:
0.00Hz
Factory default: 0.0%
Factory default:
0.00Hz
Factory default: 0.0%
Factory default:
0.00Hz
Factory default: 0.0%
Factory default: 0.0%
Factory default:
100.0%
Factory default:
0.00Hz
Factory default: 1
Factory default:
160.0%
Factory default:
0.500
Factory default: 0.0%
Factory default: 16