Param.
Designation
P10.00
Frequency Command
Pattern
Master Frequency
P10.01
Command Source
Digital Setting of Master
P10.02
Frequency
Auxiliary Frequency
P10.03
Command Source
Digital setting of auxiliary
P10.04
frequency
2: Sensor-less vector control 2
Group 10: Frequency Command
0: Master frequency command
1: Master & auxiliary computation
result
2: Switch between master and
auxiliary command
3: Switch between master
frequency command, and master
& auxiliary computation result
4: Switch between auxiliary
frequency command, and master
& auxiliary computation result
0:
Digital
setting
keypad ∧/∨ adjustment
1:
Digital
setting
terminal UP/DOWN adjustment
2: Analog input AI1
3: Analog input AI2
4: Reserved
5: X6/DI pulse input
6: Process PID output
7: PLC
8: Multi-step speed
9: Communication
Lower limit frequency ~ Upper limit
frequency
0: No command
1: Digital setting (P10.04) +
Keypad ∧/∨ adjustment
2: Digital setting (P10.04) +
terminal UP/DOWN adjustment
3: Analog input AI1
4: Analog input AI2
5: Reserved
6: X6/DI pulse input
7: Process PID output
8: PLC
9: Multi-step speed
10: Communication
Lower limit frequency ~ upper limit
frequency
- 29 -
Chapter 4 List of Parameters
Scope
(P10.02)
+
(P10.02)
+
Factory
Attr
Default
0
0
50.00Hz
00
0.00Hz