Chapter 4 List of Parameters
Param.
Designation
Terminal UP/DOWN
frequency change step
P20.18
size
FWD/REV terminal
P20.19
control mode
Option of virtual input
P20.20
terminal
P21.00
Y1 output function
Y2/DO output function
P21.01
(when used as Y2)
P21.02
Relay 1 output function
P21.03
Reserved
Scope
0.00Hz/s~100.00Hz/s
0: Two-wire mode 1
1: Two-wire mode 2
2: Three-wire mode 1
3: Three-wire mode 2
000~77F
0: Actual terminal in effect
1: Virtual terminal in effect
Unit's place: BIT0~BIT3: X1~X4
Decade: BIT4~BIT6: X5~X6,
Hundreds place: BIT8~BIT10:
AI1~AI2
Group P21 Digital Output
0: No output
1: Drive undervoltage
2: Drive running preparation
completed
3: Drive is running
4: Drive in 0Hz running (no output
at stop)
5: Drive in 0Hz running (output at
stop)
6: Running direction
7: Frequency attained
8: Upper limit frequency attained
9: Lower limit frequency attained
10: Frequency higher than FDT 1
11: Frequency higher than FDT 2
12: Reserved
13: Torque being constrained
(speed control mode)
14: Fault output
15: Alarm output
16: Drive (motor) overloaded alarm
17: Drive thermal alarm
18: Zero current detection
19: X1
20:X2
21: Motor 1/ 2 indication
22: Set count value attained
- 36 -
E5 User Manual
Factory
Attr
Default
0.03 Hz/s
0
000
0
0
14