Param.
Designation
P31.01
V/f frequency value f3
P31.02
V/f voltage value V3
P31.03
V/f frequency value f2
P31.04
V/f voltage value V2
P31.05
V/f frequency value f1
P31.06
V/f voltage value V1
P31.07
V/f frequency value f0
P31.08
V/f voltage value V0
P31.09
Torque boost
P31.10
Slip compensation gain
P31.11
Droop control
P31.12
Current limitation mode
Digital setting of current
P31.13
limit value
Current limit coeff on
P31.14
field weakening
Energy saving
P31.15
percentage
V/f oscillation
P31.16
suppression gain 1
V/f oscillation
P31.17
suppression gain 2
Voltage setting in V/f
P31.18
separated pattern
Voltage digital setting in
P31.19
V/f separated pattern
Voltage variation time in
P31.20
V/f separated pattern
P32.00
Speed/torque control
0.00Hz~rated frequency of motor
0.0%~100.0%
P31.05~P31.01
0.0%~100.0%
P31.07~P31.03
0.0%~100.0%
0.00Hz~P31.05
0.0%~100.0%
0.0%~30.0%
0.0%~400.0%
0.00Hz~mximum frequency
0: Disabled
1: Set by P31.13
2: Set by AI1
3: Set by AI2
4: Reserved
5: Set by X6/DI
20.0%~200.0%
0.001~1.000
0%~40.0%
0~3000
0~3000
0: P31.19 digital setting
1: Set by AI1
2: Set by AI2
3: Reserved
4: Process PID output
5: AI1 + process PID output
0.0%~100.0%
0.00s~600.00s
Group P32 Vector Control Parameters of Motor 1
0: speed control
1: torque control
Scope
- 43 -
Chapter 4 List of Parameters
Factory
Attr
Default
50.00Hz
100.0%
0.00Hz
0.0%
0.00Hz
0.0%
0.00Hz
0.0%
0.0%
100.0%
0.00Hz
1
160.0%
0.500
0.0%
16
20
0
0.0%
0.01s
0