3.1 Error Code Details

3.1.1 Error Code in Detail
iR C6800C / iR C6800CN / iR 5800C / iR 5800CN
Code
E000
Cause/Particulars of detection
At power-on, the rise in the temperature of the fixing assembly is not high enough.
The main thermistor (THM1, THM2, THM3), thermal switch (TP1, TP2, TP3), or
heater (H1, H2, H3, H4) has an open circuit or poor contact. The AC drive PCB or
the DC controller PCB is faulty.
0010
After power-on, the temperature does
not reach 50 deg C within 300 sec.
0011
The temperature reaches 50 deg C, but
does not reach 80 deg C within 300 sec.
0012
The temperature reaches 80 deg C, but
does not reach 110 deg C within 300
sec.
0013
The temperature reaches 110 deg C, but
does not reach 140 deg C within 300
sec.
T-3-1
Remarks
Check for an open circuit and poor
contact in the main thermistor, thermal
switch, and heater; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check for an open circuit and poor
contact in the main thermistor, thermal
switch, and heater; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check for an open circuit and poor
contact in the main thermistor, thermal
switch, and heater; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check for an open circuit and poor
contact in the main thermistor, thermal
switch, and heater; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Chapter 3