Code
Cause/Particulars of detection
02xx
The period of time between when the
home position of the intermediate
transfer belt is detected and when the
next home position is detected is
shorter than specified .
The intermediate transfer belt slips on
the drive roller, causing a delay in the
timing at which the home position is
detected.
03xx
The detection of the home position of
the intermediate transfer belt has failed
once.
ITB HP1 and ITB HP2 must occur
alternately; however, the same state has
been detected continuously.
E073
With the front door closed, the transfer drawer connector or the transfer frame
drawer connector is not connected.
0001
The result of detecting the feed unit
indicates the absence of the unit.
E077
The home position of the secondary transfer roller (engagement) is not detected.
0001
The HP sensor does not go on within 5
sec after the start of a HP search.
E078
The home position of the transfer belt cleaner unit (engagement) is not detected.
0001
The HP sensor does not go on within 5
sec after the start of a HP search.
E079
The home position of the outside heating roller is not detected.
The outside heating roller home position sensor does not go off.
0001
The HP sensor does not go on within 5
sec after the start of an HP search.
0002
If there is an open circuit in the home
position sensor of the outside heating
roller home position sensor, the state of
the sensor will be identified as being
ON.
An error will be identified if the sensor
fails to go off when it is at a point where
it must normally go on and the outside
heating roller shift motor is driven.
E100
The BD is not detected.
Remarks
Turn off the main power, and check the
surface of the intermediate transfer belt
for a tear; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB and the ITB HP
sensor; then turn on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.