ng
PCHINT
Use it to change the intervals of post rotation patch detection (video
V2
counter count).
Use it to change the intervals of patch ATR in relation to the cumulative
video count. When a specific video count is exceeded, ATR patch
detection is executed during last rotation at the end of the ongoing job,
and the limit of the cumulative video count may be changed. A higher
limit will increase the downtime intervals, but will affect the density. On
the other hand, although a lower limit will decease the downtime
intervals, the density will be more stable.
Settings range: -10 to +10 (level: 10% duty/A4)
default: 200% duty (A4, 5% duty x 40 prints)
at time of shipment/RAM initialization: 0
DLV-
Use it to change the delivery speed.
SPSW
Settings
0: delivery speed with priority on FCOT (about.635 mm/sec)
1: delivery speed with priority on paper edge damage avoidance
(about.276 mm/sec)
at time of shipment/upon RAM initialization: 0
FXMSG-
Use it to enable/disable the message that prompts replacement of the
SW
fixing assembly.
Use it to enable/disable the message on the control panel indication the
need for the replacement of the fixing assembly.
Normally, the setting is enabled; however, you can disable the message
if there is no need for replacement (so that the user will not feel
unnecessarily concerned and place a service call). If replacement is
necessary, be sure to replace it and enable the setting.
Settings
0: do not indicate
1: indicate
a time of shipment/upon RAM initialization: 1