Code
Cause/Particulars of detection
0003
The logical motor position differs
between before and after the detection
operation.
E061
At time of potential control, a specific level of potential is absent. Or, the limiter
goes on.
0001
When forming an image, the potential
is 10 V or less during initial rotation.
0002
At time of potential control, the
potential is 10 V or less during initial
rotation.
0003
While the grid bias is being adjusted, a
level of potential higher than the grid
bias is sampled.
0005
The difference in potential between
dark and light areas is less than 100 V.
0007
During adjustment of EPC offset, the
potential that is read is outside the +/-30
V range.
0008
During dark area potential adjustment,
the sampling value is too low.
0010
The sampling of the light area potential
is faulty.
E070
There is an error in the detection of the ITB home position.
xx=01: HP1, xx=02: HP2; only at ITB 1/1 speed; XX=00: no distinction
00xx
The home position of the intermediate
transfer belt is not detected within a
specific period of time .
The ITB HP sensor is faulty.
01xx
The period of time between when the
home position of the intermediate
transfer belt is detected and the next
home position is detected is longer than
specified .
The presence of a tear may have caused
the sensor to wrongly identify it as
indicating the home position.
Remarks
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off and then on the main power.
Turn off the main power, and check the
DC controller PCB and the ITB HP
sensor; then, turn on the main power.
Turn off the main power, and check the
drive of the intermediate transfer belt;
then, turn on the main power.