Chapter 1
- when detaching and attaching the drum (i.e., when the initial drum phase is lost) Here,3.
"Mechanical Work" in the detailed instructions is not needed. To avoid the possible discrepancy in phase, however,
be sure to perform 1. "Preparatory Work" and 3. "Updating the Density Initial Data."
<Detailed Instructions>
1. Preparatory Work
1-1 Turn off the main power switch, and wait until the machine has entered a ready state.
1-2 To stabilize the machine operation, generate 5 test pattern printouts (A3, double-sided) by executing the
following in service mode: COPIER>TEST>PG>TYPE=16.
Be sure not to forget to select a cassette loaded with A3 paper and double-sided printing in service mode.
- to select a particular cassette in service mode, execute COPIER>TEST>PG>PG-PICK=3 or =4.
- to select double-sided printing in service mode, execute COPIER>TEST>PG>2-SIDE=1.
1-3
Set
"1"
to
the
following
service
mode
to
disable
initial
multiple
rotation:
COPIER>FUNCTION>INSTALL>AINR-OFF.
1-4 Turn off the main power switch.
2. Mechanical Work
2-1 Open the front cover.
2-2 Shift down the fixing/feeding release lever [1], and draw out the fixing/feeding assembly [2] to the front.
[1]
[2]
F-1-2
2-3 Open the color toner supply cover [1]. Remove the 2 screws [2], and detach the process cover [3].
[2]
[3]
[1]
F-1-3
2-4 Remove the screw [1], and shift down the primary transfer roller locking lever [2] (so that the primary transfer
1-25