Error Code; Error Code Details - Canon imageRUNNER 1750 Series Service Manual

Hide thumbs Also See for imageRUNNER 1750 Series:
Table of Contents

Advertisement

Error Code

Error Code Details

Detail
Ecode
Item
Code
E000 0001
Title
Fixing temperature rising error
Description The detected temperature of the Main Thermistor failed to reach the
specified temperature at temperature rising control.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).
E001 0000
Title
Detection of overheating of Fixing Assembly
Description The Main Thermistor detected 250 deg C or higher for 200 msec or
longer on end.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).
E001 0001
Title
Detection of overheating of Fixing Assembly
Description The hardware circuit detected overheating of the Main Thermistor or
Sub Thermistor for 30 msec or longer.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Replace the DC Controller PCB (PCB1).
E001 0002
Title
Detection of overheating of Fixing Assembly
Description The Sub Thermistor detected 295 deg C or higher for 200msec or
longer on end.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).
7
Error Code > Error Code > Error Code Details
Description
7
Error Code > Error Code > Error Code Details
Detail
Ecode
Item
Code
E002 0000
Title
Error in temperature rising of Fixing Assembly
Description 1. The Main Thermistor detected a temperature lower than 115 deg C
for 400 msec or longer on end 6.0 seconds after the Main Thermistor
detected 100 deg C.
2. The Main Thermistor detected a temperature lower than 150 deg C
for 400 msec or longer on end 6.0 seconds after the Main Thermistor
detected 140 deg C.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).
E003 0000
Title
Detection of fixing low temperature during printing
Description The Main Thermistor detected a temperature lower than 80 deg C
for 200 msec or longer on end, or the Sub Thermistor detected a
temperature lower than 60 deg C for 200 msec or longer on end.
Remedy
1. Go through the following to clear the error: CLEAR > ENGIN >
ERRCLR in Service Mode; then, turn OFF and then ON the power.
2. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
3. Replace the Fixing Assembly.
4. Replace the DC Controller PCB (PCB1).
E004 0000
Title
Thermistor disconnection detection error
Description Connector disconnection was detected for 30 msec on end.
Remedy
1. Check the connector connection. (J206 on the DC Controller PCB,
J101 on the Power Supply PCB)
2. Replace the Fixing Assembly.
3. Replace the DC Controller PCB (PCB1).
E010 0001
Title
Main Motor (M2) rotation error
Description Detection was performed every 100 msec since the start of drive and
there had been no lock detection signal in 2 seconds.
Remedy
1. Check the connector between the Main Motor and the DC Controller
PCB (J203).
2. Replace the Main Motor (M2).
3. Replace the DC Controller PCB (PCB1).
E010 0002
Title
Main Motor (M2) rotation error
Description Detection was performed every 100msec during the drive (after the lock
detection) and the lock signal was not detected 5 times in a row (in 500
msec).
Remedy
1. Check the connector between the Main Motor and the DC Controller
PCB (J203).
2. Replace the Main Motor (M2).
3. Replace the DC Controller PCB (PCB1).