COPIER>FUNCTION>PART-CHK
Subheadin
Contents
Level
g
FAN-ON
Use it to start the operation of the fan
Method of Operation
1) Select the item, and press the OK key to start the following:
in the case of FAN= 1,2,5,7,10
for 10 sec, ON at full speed>for 10 sec, ON at half-speed>standby
1
Copier Heat Exhaust Fan, Delivery Cooling Fan, Manual Feed
Cooling Fan
in the case of FAN= 3,4,6,9
for 10 sec, ON at full speed>standby