Code
Cause/Particulars of detection
E001
The rise in the temperature of the fixing assembly is excessive.
There is an open circuit or poor contact in the following: main thermistor (THM1,
THM2, THM3), sub thermistor (THM4, THM5, THM6), or heater (H1, H2, H3,
H4). The AC driver PCB or the DC controller PCB is faulty.
0001
The rise in the temperature of the fixing
roller is excessive.
0002
The rise in the temperature of the
outside heating roller is excessive.
0003
The rise in the temperature of the
pressure roller is excessive.
E002
The rise in the temperature of the fixing assembly is not enough.
There is an open circuit or poor contact in the main thermistor (THM1, THM2,
THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC
driver PCB or the DC controller PCB has a fault.
0010
The temperature of the fixing roller
reaches 80 deg C, but drops below 50
deg C.
0020
The temperature of the outside heating
roller reaches 80 deg C, but drops
below 50 deg C.
Remarks
Check the main thermistor, sub
thermistor, and heater for an open
circuit and poor contact; then, reset in
service mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, sub
thermistor, and heater for an open
circuit and poor contact; then, reset in
service mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, sub
thermistor, and heater for an open
circuit and poor contact; then, reset in
service mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.