Code
Cause/Particulars of detection
0030
The temperature of the pressure roller
reaches 80 deg C, but drops below 50
deg C.
E003
After standby, the drop in the temperature of the fixing assembly is excessive.
There is an open circuit or poor contact in the main thermistor (THM1, THM2,
THM3), thermal switch (TP1, TP2, TP3), or heater (H1, H2, H3, H4). The AC
driver PCB or the DC controller PCB has a fault.
0041
During standby, the temperature of the
fixing roller drops below 150 deg C.
0042
During standby, the temperature of the
outside heating roller drops below 190
dg C.
0043
During standby, the temperature of the
pressure roller drops below 120 deg C.
0051
During copying, the temperature of the
fixing roller drops below 150 deg C.
0052
During copying, the temperature of the
outside heating roller drops below 190
deg C.
Remarks
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.
Check the main thermistor, thermal
switch, and heater for an open circuit
and poor contact; then, reset in service
mode:
COPIER>FUNCTION>CLEAR>ERR
.