Code
Cause/Particulars of detection
0001
The BD signal is not detected when the
polygon scanner has been driven for a
specific period of time.
0002
The BD signal is not detected white the
polygon scanner is rotating stably.
E110
There is a scanner motor error.
0001
The FG signal is not detected within a
specific period of time after the
polygon scanner has been driven.
0002
The FG signal is not detected while the
polygon scanner is rotating stably.
0003
The FG signal is not detected while the
polygon scanner is rotating stably.
E197
There is an error in the communication with the fixing feed PCB.
In the course of initializing
communication between the DC
0002
controller and the fixing/feeding unit,
as many as 10 communication errors
occur continuously.
Following the end of initialization of
the communication between the DC
0003
controller and the fixing/feeding unit,
as many as 10 communication errors
occur continuously.
At the start of drum initial multiple
rotation, there is no signal indicating
0004
the start of 24V in the fixing assembly
in the communication between the DC
controller and the fixing/feeding unit.
E202
There is an HP error.
0001
An error is found during the forward
trip of the HP search.
The scanner HP sensor is faulty. The
scanner motor is faulty. The reader
controller is faulty.
Remarks
Turn off the main power, and check the
DC controller PCB and the 24V system
fuse; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB and the 24V system
fuse; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB and the 24V system
fuse; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB and the 24V system
fuse; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB and the 24V system
fuse; then, turn on the main power.
Turn off the main power, and check the
DC controller PCB wiring and the 24V
system fuse; then, turn on the main
power.
Turn off the main power, and check the
DC controller PCB wiring and the 24V
system fuse; then, turn on the main
power.
Turn off the main power, and check the
DC controller PCB wiring and the 24V
system fuse; then, turn on the main
power.
Check the harness connector for
connection; then, as necessary, replace
the faulty part.