Subheadin
g
100DF-RG
Use it to indicate the degree of offset (color displacement; RG) for
ADF mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or
replaced the reader controller PCB, enter the value indicated on the
service label.
Range of Adjustment: -256 to 256
at time of shipment: factory measurement value
upon initialization: 0
Attention
If you have changed the setting, be sure to record the new setting on
the service label.
100DF-GB
Use it to indicate the degree of offset (color displacement; GB) for
ADF mode at 100% reading.
Method of Adjustment
- if you have initialized the RAM on the reader controller PCB or
replaced the reader controller PCB, enter the value indicated on the
service label.
Range of Adjustment: -256 to 256
at time of shipment: factory measurement value
upon initialization: 0
Attention
If you have changed the setting, be sure to record the new setting on
the service label.
COPIER>ADJUST>CCD
Contents
Level
1
1