Chapter 5
Subheadin
HVRATE-
3
HVRATE-
2
<HV-TR>
Subheadin
PRE-TR
5-70
COPIER>ADJUST>HV-PRI
g
Use it to adjust the parameter settings for primary charging bias/laser
power (at feed speed 1/3).
Method of Adjustment
- adjust the parameter setting for the primary charging bias/laser power
for when 1/3 feed speed is used.
Range of Adjustment: 0 to 100 (in increments of 1)
at time of shipment/upon RAM initialization: 33
Use it to adjust the parameter setting for primary charging bias/laser
power (at feed speed 2/3).
Method of Adjustment
- adjust the parameter setting for the primary charging bias/laser power
for when 2/3 feed speed is in use.
Range of Adjustment: 0 to 100 (in increments of 1)
at time of shipment/upon RAM initialization: 33
COPIER>ADJUST>HV-TR
g
Use it to adjust the current for the pre-transfer charging assembly.
Range of Adjustment: -200 to 200 (unit: 5.0 yA)
at time of shipment: factory adjustment value
upon RAM initialization: 0