Testing The Sensors - GRAPHTEC CUTTING PRO FC3100-60 Service Manual

Table of Contents

Advertisement

5.14 Testing the Sensors

Run this test whenever a sensor has malfunctioned or has been replaced.
(1) Set the SW1 DIP switch as shown below and then turn on the plotter.
* Set only Bits 1, 2 and 8 to OFF
(2) The status of each sensor is displayed on the LCD panel.
Display
Sensor name
Hm
Y home sensor
Cm
Cam sensor
+ X
Rear paper size sensor
- X
Front paper size sensor
(3) If a sensor is not operating properly, check its wiring, its connector contact, and the position of the
sensor dog. If everything checks out all right, either the sensor or main board may be defective.
In this case, initialize the NOV-RAM and then run the sensor test again.
(4) As a temporary measure for dealing with a defective sensor, turn off the plotter, set Bit 4 of the DIP
switch to OFF, and then turn the plotter back on.
Note : When the plotter is turned back on, the pen position becomes the plot area's origin (0,0) and the
plotter is not initialized.
For more information, see Chapter 6, "TEMPORARY MEASURES FOR A SENSOR
MALFUNCTION".
Operation when the High/Low level changes
When the dog blocks the sensor
Same as the above
While detecting the paper size
Same as the above
5 - 18
FC3100-60 Service Manual
P/N53802-031T Rev. A
L