6-3
Problems in the Feed Section
6-3-2 The feed rotor does not rotate
Check
The main motor
circuit breaker
(Q11) is switched
off.
6-3-3 The vacuum piston moves slowly
Check
The vacuum pis-
ton does not
move smoothly.
6-3-4 The feed table does not move up and down
Check
The feed table
motor circuit
breaker (Q20) is
switched off.
6-3-5 The right end of the sheet moves
Check
The suction
length is too
short.
Cause and Recovery
- Switch on the circuit breaker.
23051
60302A1
Cause and Recovery
- Disassemble and clean the suction piston.
Piston Set Screw
(Do not over-tighten the piston set screw.)
23051
60303A1
Cause and Recovery
- Switch on the circuit breaker.
23051
60304A1
Cause and Recovery
- Increase the suction length using the Main-
Condition screen.
23051
60305A1