Connecting The Power Cables; Pump Rotation Direction - Horizon Fitness AFC-566F Manual

Cross folder
Table of Contents

Advertisement

8-6

Connecting the Power Cables

WARNING
If you
will be connecting the main power cable
directly to a circuit breaker in the factory's distribu-
tion board, have this done by a qualified electrician.
Turn off the circuit breaker in the fac-
tory's distribution board.
Connect the power cable from the
machine to the distribution board.
- Be sure to connect the ground.
Turn on the circuit breaker on the dis-
tribution board.
Turn on the power switch.
8-7

Pump Rotation Direction

Check the direction of rotation of the fan on the pump
to see whether the power cable is connected cor-
rectly.
Turn on the main power switch.
Raise the feed table.
Place the pump so that you can check
the fan.
Keep watching the fan as you start
the pump.
- Press the Motor/Feed Start button on the con-
trol panel to start the pump.
- If the fan rotates clockwise, this is normal. If it
rotates counterclockwise, press the Emergency
Stop button immediately. If you let the fan rotate
counterclockwise for a long time, the pump will
be damaged.
If the fan rotates counterclockwise,
do the following:
(1) Turn off the power switch.
(2) Exchange the connections for the red and
white wires connected to the terminal board.
Factory Circuit Breaker
Capacity 15 A
3-phase 200V,
220V, 400V
Connect the
power cables.
Here is a fan inside.
White
Red
23051
80401C1
23051
80401A1
Motor/Feed Start
Button
Feed Table Up
Button
23051
80401B1
145