3-5
Setting the Suction Head
Start the pump.
- Press the Feed Start button on the control panel
once.
- The air blowers will start, and the vacuum piston
will grip the top sheet and lift it.
Adjust the pump pressure.
- Adjust the vacuum and the pressure regulator
knobs so that the vacuum gauge is set to - 0.04
MPa (-5.8 psig) and the pressure gauge is set
to 0.03 to 0.04 MPa (4.4 to 5.8 psig).
Adjust the blower pressure.
- Adjust the blower air using the blower position
adjusting knobs and the blower pressure adjust-
ing knobs. About 10 to 15 sheets at the top of
the stack should be separated.
In normal use, both of the blower pressure
adjusting knobs are set evenly. If the sheets
are distorted on both sides of the suction cup
because the sheets are curved, adjust the gap
using the blower pressure adjusting knobs.
If the blower pressure is too strong, this can
cause double feeding.
Vacuum Gauge
Pressure Gauge
Vacuum Regulator
Knob
Blower Pressure
Adjusting Knobs
0
MAX
0
Blower Air Nozzle
Separation Air
23051
30501C1
Pressure Regulator
Knob
23051
30501D1
Blower Position
Adjusting Knobs
0
MAX
0
10 to 15
Sheets
Separator
23051
30501E1
47