The Folded Edge Of The Signature Swells Up; The Knife Does Not Work; The Roller Below The Knife Does Not Rotate - Horizon Fitness AFC-566F Manual

Cross folder
Table of Contents

Advertisement

6-7
Problems in the Knife Section

6-7-4 The folded edge of the signature swells up

Check
The gap for the
fold roller (on the
side with the
folds) is too wide.

6-7-5 The knife does not work

Check
The knife func-
tion is turned off.
The knife servo
amplifier circuit
breaker (Q40) is
switched off.

6-7-6 The roller below the knife does not rotate

Check
The motor circuit
breaker below the
knife (Q12) is
switched off.
Cause and Recovery
- Reduce the gap on the side with the folds.
23051
60502B1
Cause and Recovery
- Turn on the knife function using the manual
setup on the Setup - Guide - Buckle screen.
23051
60705A1
- Switch on the circuit breaker.
23051
60705B1
Cause and Recovery
- Switch on the circuit breaker.
23051
60706A1