RADWAG WLY User Manual page 131

Y series
Hide thumbs Also See for WLY:
Table of Contents

Advertisement

Give number
[ET]
of batching
repetitions
[F]
Set flags
[CF]
Flags condition
Gravitational
[DG]
dosing
Mass
Percent
Product
Time correction
Insensibility
threshold
Minimal flow
Weighing in minus
Function determining quantity of batches of
weighed ingredient, that is added to a dosing
process. Mass of a single batch is determined
in a product selected from the database
(Products database – field Mass). Product's
mass is multiplied by a specific value, and such
determined mass is added to weighing process.
The function is applicable for weighing products
in batches.
Function determining a condition (characteristic
point) in dosing process. The function enables
conditional carrying out another step in dosing
process. Setting the characteristic point (signal
flags) in connection with condition flags enables
mutual conditioning of different processes on
different weighing platforms.
Conditional function determining criteria for
events, which have to occur in order to carry
out the following step in dosing process.
Function activating operation of automatic
weighment (automatic dosing), with option of
dosed mass flow measurement.
Mass of a component which is to be dosed-out
Mass threshold, given as a percentage [%],
automatic dosing is realized within this
threshold
Dosing process component selected from
product database
Time correction ± of closing a valve during the
dosing process, given as [ms]
Permissible error ± of dosed-out mass, given
as a percentage [%]
Minimal flow value given as [g/s] or [kg/s] for an
initiated algorithm of gravitational dosing
Allows for turning on weighing in minus mode
131

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wpy

Table of Contents