Local Setting Of A Working Mode - RADWAG WLY User Manual

Y series
Hide thumbs Also See for WLY:
Table of Contents

Advertisement

A dosing process can be searched in a database by:
the name of a dosing process <
the code of a dosing process <
Processes carried out on different weighing platforms operated by the same
terminal, can also be dependent on each other, e.g.: dosing on weighing
platform 2 can be initiated only on completing dosing on weighing platform 1,
which is confirmed by a signal from appropriate sensor.

28.3. Local setting of a working mode

Local settings for the working mode <
on pressing a hot key <
Local parameters>:
Ask for multiplier
Ask for number of cycles
Confirm batching
ingredients manually
No. of weighments for
calculating the correction
Automatic cycle
Global
Batching outputs
Bulk batching output
Correction
Maximum correctional
value
>
>
Dosing> are accessible
Causes setting a question for dosing
process multiplier, i.e. the number which is
used to multiply the values of mass of all
components.
Causes setting a question on number of
dosing process cycles, i.e. number of
repetitions of the same process.
Causes enabling manual confirmation by
pressing "Enter/Print" key on terminal's
keyboard for each weighing process.
Determines the number of recent
measurements which are analysed for
calculating automatic correction in dosing
Enables an already initiated process to be
performed in a cyclic manner
Global settings of dosing process
Enables setting the outputs for dosing (fine
dosing in case of two-step dosing process)
Enables setting outputs for bulk dosing in
case of two-step dosing process
Enables determining global value of
correction for all weighing platforms
Enables determining maximal value of
correction, which can be automatically
determined for all weighing platforms
128

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wpy

Table of Contents