Appendix 2 Devices That Support Iq Sensor Solution; Cpu Module - Mitsubishi Electric IQSS-R-E Reference Manual

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

Appendix 2
This section shows the list of the available devices for iQ Sensor Solution.

CPU module

The following shows the CPU modules available for each connection method for iQ Sensor Solution.
: Supported, : Not supported
Type
Model name
*1
RCPU
R00CPU
, R01CPU, R02CPU
R04CPU, R08CPU, R16CPU, R32CPU, R120CPU
R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU,
R120ENCPU
R08PCPU, R16PCPU, R32PCPU, R120PCPU
R08PSFCPU, R16PSFCPU, R32PSFCPU,
R120PSFCPU
R08SFCPU, R16SFCPU, R32SFCPU, R120SFCPU
FX5CPU
FX5U-32MR/DS, FX5U-32MR/ES, FX5U-32MT/DS,
FX5U-32MT/DSS, FX5U-32MT/ES, FX5U-32MT/ESS,
FX5U-64MR/DS, FX5U-64MR/ES, FX5U-64MT/DS,
FX5U-64MT/DSS, FX5U-64MT/ES, FX5U-64MT/ESS,
FX5U-80MR/DS, FX5U-80MR/ES, FX5U-80MT/DS,
FX5U-80MT/DSS, FX5U-80MT/ES, FX5U-80MT/ESS,
FX5UC-32MT/D, FX5UC-32MT/DSS, FX5UC-64MT/D,
FX5UC-64MT/DSS, FX5UC-96MT/D, FX5UC-96MT/
DSS, FX5UC-32MT/DS-TS, FX5UC-32MT/DSS-TS
*15,*1
LCPU
L02CPU, L02CPU-P, L06CPU, L06CPU-P, L26CPU,
6
L26CPU-P, L26CPU-BT, L26CPU-PBT
QCPU
Q03UDVCPU, Q04UDVCPU, Q06UDVCPU,
Q13UDVCPU, Q26UDVCPU
*25
FXCPU
FX3G, FX3GC
, FX3U
*1 The data backup/restoration function cannot be used on these modules with no SD memory card slot.
*2 Modules a firmware version of which is 05 or later support it.
*3 Only built-in Ethernet port CPUs support it. (Connection via an Ethernet port of an Ethernet module is not supported.)
*4 Modules a firmware version of which is 22 or later support it.
*5 Modules a firmware version of which is 35 or later support it.
*6 Modules a firmware version of which is 03 or later support it.
*7 Modules a firmware version of which is 22 or later support a data backup and restoration.
*8 Modules a firmware version of which is 25 or later support it.
*9 Modules a firmware version of which is 12 or later support it.
*10 Modules a firmware version of which is 25 or later support a data backup and restoration with a program.
*11 Only the Ethernet port of the CPU part (CPU P1) can be used for iQ Sensor Solution functions.
The Ethernet ports of the network part (P1/P2) are not available.
For the part names of RnENCPUs, refer to the following manual.
MELSEC iQ-R Ethernet/CC-Link IE User's Manual (Startup)
*12 The data backup/restoration function is not supported.
*13 It is not available in a redundant line configuration.
For a redundant line configuration, refer to the following manual.
MELSEC iQ-R CC-Link IE Field Network User's Manual (Application)
*14 Modules a firmware version of which is 1.040 or later support it.
*15 Modules with a serial number whose first five digits are '15052' or higher support the devices connected to communication unit for CC-
Link.
*16 Modules with a serial number whose five digits are '16042' or higher support the devices supporting iQSS which are connected to a
bridge module.
*17 Modules with a serial number whose first five digits are '14112' or higher support the data backup/restoration function.
*18 Modules with a serial number whose first five digits are '16072' or higher support the data backup/restoration function.
*19 Modules with a serial number whose first five digits are '18112' or higher or later support it.
*20 Modules with a serial number whose first five digits are '15043' or higher support it.
Devices that Support iQ Sensor Solution
Connection method
AnyWireASLIN
K
*4
*4
*12
*12
*17
*22
*26
*26
*12
, FX3UC
CC-Link
CC-Link IE
CC-Link IE
Field
Field
Network
Network
Basic
*2
*5
*6,*7
*5
*4
*12,*13
*12,*13
*12,*13
*17
*18
*22
*23

Appendix 2 Devices that Support iQ Sensor Solution

Ethernet
*3
*8
*3,*9,*10
*8
*3,*9,*11
*14
*19
*3,*20,*21
*19
*3,*24
APPX
325
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents