Mitsubishi Electric IQSS-R-E Reference Manual page 102

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

2. Select
Select
• The system configuration cannot be detected if an error occurs on the master station.
Take the corrective actions and perform an automatic detection of connected devices again.
• Error information is displayed in the "Output" window when an error occurred.
Double-click it and correct the error at the jumped destination.
• When a module which is not a device supporting iQSS is detected, it is displayed as "General Module".
• When "General Module" is displayed, it can be changed to "General CC IE Field Module" by the following
operation:
Select the target module, and select [CC IE Field Configuration]  [Change Module]  [Change to General
CC IE Field Module].
5 CC-Link IE Field Network
100
5.1 Detecting Devices Supporting iQSS Automatically
1. Enter
Select
List of stations
Device map area
Output window
7.
Enter the start device and end device to the "RX/RY Setting"
and "RWw/RWr Setting" and select [CC IE Field
Configuration]  [Close with Reflecting the Setting] in the
"CC IE Field Configuration" window.
8.
Write data to the CPU module and open the "CC IE Field
Configuration" window again.
9.
Select [CC IE Field configuration]  [Online]  [Detect Now]
in the "CC IE Field Configuration" window.
10.
Read the message and click the [Yes] button.
The actual system configuration is displayed in the "CC IE Field
Configuration" window.
11.
Select [CC IE Field Configuration]  [Close with Reflecting
the Setting] in the "CC IE Field Configuration" window.
The setting in the "CC IE Field Configuration" window is applied to
the network parameter and completed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents