Error code
Error and cause
CEE1H to
System error
CEE2H
CF10H
System error
CF20H
• The setting value of the communication setting is out of
the range.
• The items of communication setting which cannot be set
on the target device supporting iQSS were set.
• The required setting items have not been set to the target
device supporting iQSS.
CF30H
The parameter which is not supported by devices
supporting iQSS was specified.
CF31H
System error
CF41H
The required information for monitoring could not be
obtained from the devices supporting iQSS.
CF50H
System error
CF51H
The function could not be performed because the other
peripheral devices are in process.
CF52H
The required information for monitoring could not be
obtained from the devices supporting iQSS.
CF53H to
System error
CF56H
CF60H to
At the data backup for the iQ Sensor Solution function (data
CF61H
backup/restoration), the process cannot be started.
CF62H
At the data backup for the iQ Sensor Solution function (data
backup/restoration), the process cannot be terminated.
CF63H
At the data restoration for the iQ Sensor Solution function
(data backup/restoration), the device supporting iQSS of
the specified backup data and the one as data restoration
target are not inconsistent.
CF64H
At the data restoration for the iQ Sensor Solution function
(data backup/restoration), the process cannot be started.
CF65H
At the data restoration for the iQ Sensor Solution function
(data backup/restoration), the process cannot be
terminated.
APPX
352
Appendix 5 Error Code List
Corrective action
• Check the considerations for the performed function.
• Check the operating status and connection status of the devices
supporting iQSS.
• Check the connection of Ethernet cable and a hub.
• Check the Ethernet line status.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
Review the settings and retry.
Check the version of devices supporting iQSS.
• Check the considerations for the performed function.
• Check the operating status and connection status of the devices
supporting iQSS.
• Check the connection of Ethernet cable and a hub.
• Check the Ethernet line status.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
• Check the operating status and connection status of the devices
supporting iQSS.
• Reset the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
• Check the considerations for the performed function.
• Check the operating status and connection status of the devices
supporting iQSS.
• Check the connection of Ethernet cable and a hub.
• Check the Ethernet line status.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
Retry after a while.
• Check the operating status and connection status of the devices
supporting iQSS.
• Reset the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
• Check the considerations for the performed function.
• Check the operating status and connection status of the devices
supporting iQSS.
• Check the connection of Ethernet cable and a hub.
• Check the Ethernet line status.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
• Check the operating status and connection status of the devices
supporting iQSS.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.
Check the devices supporting iQSS (manufacturer, model name, version) of
the specified backup data and the restoration target.
• Check the operating status and connection status of the devices
supporting iQSS.
• Reset the CPU module and the devices supporting iQSS and retry.
If the problem persists, contact the manufacturer of the devices supporting
iQSS.