Mitsubishi Electric IQSS-R-E Reference Manual page 362

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

Number
Name
SD1452
iQ Sensor Solution
backup/restoration error
cause in a module
SD1453
iQ Sensor Solution
backup/restoration error
cause in a device
SD1454
iQ Sensor Solution
backup/restoration error
module/execution unit
information
SD1455
iQ Sensor Solution
backup/restoration error
folder number
information
SD1456
iQ Sensor Solution
backup/restoration error
module information
SD1457
iQ Sensor Solution
backup/restoration error
device information
(target device 1)
APPX
360
Appendix 6 Special Relay (SM)/Special Register (SD) List
Description
Details
Storing the cause of the
This register stores the cause of the data backup/restoration error
data backup/restoration
detected in a module.
error detected in a
When errors are detected in multiple devices, the error detected first is
module
stored.
A value is cleared to '0' when the right-to-use is acquired.
For details on the stored error cause, refer to the following section.
• MELSEC-L CPU Module User's Manual (Hardware Design,
Maintenance and Inspection)
•  QCPU User's Manual (Hardware Design, Maintenance and
Inspection)
•  User's manual for the data backup/restoration target module
Storing the cause of the
This register stores the cause of the data backup/restoration error
data backup/restoration
detected in a target device.
error detected in a device
When errors are detected in multiple devices, the error detected first is
stored.
A value is cleared to '0' when the right-to-use is acquired.
For details on the stored error cause, refer to the following section.
• Page 347 Error Code List
•  User's manual for the data backup/restoration target module
Storing the information of
This register stores the target module type and execution unit
target module/execution
information when a data backup/restoration error occurred.
unit when data backup/
■Lower 8 bits (target module type)
restoration error occurred
• 1H: AnyWireASLINK
• 2H: CC-Link
• 3H: Ethernet
• 4H: CC-Link IE Field Network
■Upper 8 bits (execution unit)
<AnyWireASLINK>
• 1H: Module unit
• 2H: ID unit
<CC-Link, CC-Link IE Field Network>
• 1H: Module unit
• 2H: Station unit
• 3H: Station sub-ID unit
<Ethernet>
• 1H: Module unit
• 2H: IP address unit
When errors are detected in multiple devices, the information of the
device where the error is detected first is stored.
A value is cleared to '0' when the right-to-use is acquired.
Storing the target folder
This register stores the target folder number (0 to 99) when a data
number when a data
backup/restoration error occurred.
backup/restoration error
If the folder number cannot be identified, 'FFFFH' will be stored.
occurred
A value is cleared to '0' when the right-to-use is acquired.
Storing the information of
This register stores the information of the target device (target module)
the target device (target
where a data backup/restoration error occurred.
module) where a data
• Start I/O No.
backup/restoration error
• 03FFH: Built-in Ethernet
is detected first
When errors are detected in multiple devices, the information of the
target device (target module) where the error is detected first is stored.
A value is cleared to '0' when the right-to-use is acquired.
Storing the information of
This register stores the information of the device (target device 1)) where
the target device where a
a data backup/restoration error occurred.
data backup/restoration
<AnyWireASLINK>
error is detected first
• ID number
<CC-Link, CC-Link IE Field Network>
• Station number
<Ethernet>
• IP address (lower 16 bits)
When errors are detected in multiple devices, the information of the
device (target device 1) where the error is detected first is stored.
A value is cleared to '0' when the right-to-use is acquired.
*6
: Module
Set by
(setting
timing)
S (status
change/error)
S (status
change/error)
S (status
change/error)
S (status
change/error)
S (status
change/error)
S (status
change/error)

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents