Data restoration

Information saved in an SD memory card can be restored to a device supporting iQSS for each IP address by using an
engineering tool.
Operating procedure
1. Select
2. Click
The initial value of the restoration setting (SD1444) is as follows:
• Lower 8 bits of SD1444 (operation setting on error): 0H (continue)
Use a program when restoring data with the settings other than above. (Page 157 Program execution for
data restoration)
6 Ethernet
156
6.5 Backing up/Restoring Data of Devices Supporting iQSS
2. Select
1. Select
1.
Select a target device supporting iQSS in 'List of devices' or
'Device map area' in the "Ethernet Configuration" window,
and select [Ethernet Configuration]  [Online]  [Restore
Ethernet Device].
2.
Select backup data to be restored, and click the [Execute]
button.
A list of the backup folder names (date_number) is
displayed in the column of "Folder Name".
Backup data is stored in backup folders for each
folder name (Target module_IP address) in an SD
memory card.
For details on the backup folder configuration,
refer to the following section.
Page 145 Backup folder configuration
3.
Read the message, and click the [OK] button.