Mitsubishi Electric IQSS-R-E Reference Manual page 365

Iq sensor solution, melsec iq-r/iq-f/l/q series, got2000, melipc
Table of Contents

Advertisement

MELSEC iQ-R series
The following table lists the special registers (SD) used for MELSEC iQ-R series.
Number
Name
SD604
SD memory card (drive
2) usage status
SD1360
iQ Sensor Solution
backup/restoration right-
to-use request number
SD1361
iQ Sensor Solution
backup/restoration right-
to-use acquisition
number
SD1362
iQ Sensor Solution
backup/restoration
target module,
execution unit setting
SD1363
iQ Sensor Solution
backup/restoration
folder number setting
SD1364
iQ Sensor Solution
backup/restoration
target setting (target
module)
SD1365
iQ Sensor Solution
backup/restoration
target setting (target
device 1)
Description
Details
SD memory card (drive
This register stores the usage status of an SD memory card in the
2) usage status
following bit pattern. (Each bit is ON while the memory card is being
used.)
• b0: Event history
• b1: Module extended parameter
• b2: Label communication data
• b3 to b15: Not used
Backup/restoration right-
This register sets a request number (arbitrary four-digit number) to
to-use request number
acquire/release a right to use. Use the following request number
depending on the request source.
• 0000H: Right-to-use release request
• 1***H: Request from a program
• D***H: Request from MELSOFT Navigator
• E***H: Request from GOT
• F***H: Request from an engineering tool (GX Works3)
Backup/restoration right-
This register stores the request number with which a right to use is
to-use acquisition
acquired after receiving the iQ Sensor Solution data backup/restoration
number
use request. (0000H is stored when a right to use is not acquired or has
been released.)
Backup/restoration target
This register is used to set a target module type and execution unit for iQ
module, execution unit
Sensor Solution backup/restoration.
■Lower 8 bits (target module type)
setting
• 1H: AnyWireASLINK
• 2H: CC-Link
• 3H: Ethernet
• 4H: CC-Link IE Field Network
■Upper 8 bits (execution unit)
<AnyWireASLINK>
• 1H: Module unit
• 2H: ID unit
<CC-Link, CC-Link IE Field Network>
• 1H: Module unit
• 2H: Station unit
• 3H: Station sub-ID unit
<Ethernet>
• 1H: Module unit
• 2H: IP address unit
■Example (execution unit: ID unit (2H), target module: AnyWireASLINK
(1H))
201H
Backup/restoration folder
This register is used to set the number of a folder in which a backup data
number setting
is to be stored or a folder that contains data for restoration.
• 0 to 99: Target folder specification
• FFFEH: Automatic specification (folder deletion supported)
• FFFFH: Automatic specification (default)
Backup/restoration target
This register is used to set a target module for iQ Sensor Solution
setting (target module)
backup/restoration.
• Start I/O No.
• 03FFH: Built-in Ethernet
Backup/restoration target
This register is used to set a target device for iQ Sensor Solution
setting (target device 1)
backup/restoration.
<AnyWireASLINK>
• ID number
<CC-Link, CC-Link IE Field Network>
• Station number
<Ethernet>
• IP address (lower 16 bits)
*1
*2
: Module
*3
Appendix 6 Special Relay (SM)/Special Register (SD) List
Set by
(setting
timing)
S (status
change)
U
S (status
change)
U
A
U
U
U
APPX
363

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28