Detecting devices connected to a bridge module (NZ2AW1C2AL)

To display devices supporting iQSS, which are connected to a bridge module (NZ2AW1C2AL), on a system configuration
diagram, first a bridge module (NZ2AW1C2AL) needs to be detected in the "CC-Link Configuration" window. Then, perform an
automatic detection of connected devices in the "AnyWireASLINK Configuration" window in order to detect and display
devices supporting iQSS which are connected to a bridge module (NZ2AW1C2AL).
For the considerations when detecting devices supporting iQSS connected to a bridge module (NZ2AW1C2AL), refer to the
following section.
Page 61 Considerations when detecting devices connected to a bridge module
System configuration
CPU module
CC-Link master/local module
ASLINKAMP (Input)
Type
CPU module
LCPU
CC-Link master/local module
CC-Link-AnyWireASLINK bridge module
ASLINKAMP (Input)
Photoelectric sensor
Fiber sensor
ASLINKER (Input)
■Setting the operation mode for CC-Link Ver.2-compatible slave station
A bridge module (NZ2AW1C2AL) is a CC-Link Ver.2-compatible slave station.
To detect and display a bridge module (NZ2AW1C2AL) on a system configuration diagram, set the operation mode in which
CC-Link Ver.2-compatible slave station works.
The following table shows the combinations of the parameter setting for a CC-Link master/local module and the CC-Link
operation mode for a bridge module (NZ2AW1C2AL).
CC-Link master/local module (L26CPU-BT, L26CPU-PBT, LJ61BT11, QJ61BT11N)
Parameter setting item
Mode
Remote net Ver.2 mode
Remote net additional mode
For the information of the version and mode of CC-Link, refer to the following manuals.
• MELSEC-Q CC-Link System Master/Local Module User's Manual
• MELSEC-L CC-Link System Master/Local Module User's Manual
• CC-Link-AnyWireASLINK Bridge Module User's Manual
CC-Link-AnyWireASLINK bridge module
Model name
L26CPU-BT
LJ61BT11
NZ2AW1C2AL
B289SB-01AP-CAM20 (ASLINKAMP master)
B289SB-01AP-CAS (ASLINKAMP slave)
B289SB-01AF-CAS (ASLINKAMP slave)
B289SB-01AF-CAS (ASLINKAMP slave)
B281SB-02U-CC20
Station information (station type)
Ver.2 remote device station
ASLINKER (Input)
Manufacturer
Mitsubishi Electric Corporation
AnyWire Corporation
Bridge module (NZ2AW1C2AL)
CC-Link operation mode
Ver.2.00
4.1 Detecting Devices Supporting iQSS Automatically
4
4 CC-Link
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

13jv28

Table of Contents